PLLS=0, CME0=0, VDIV=0, LOLIE0=0
MCG Control 6 Register
VDIV | VCO Divider 0 (0): Multiply Factor is 16 1 (1): Multiply Factor is 17 2 (2): Multiply Factor is 18 3 (3): Multiply Factor is 19 4 (4): Multiply Factor is 20 5 (5): Multiply Factor is 21 6 (6): Multiply Factor is 22 7 (7): Multiply Factor is 23 8 (8): Multiply Factor is 24 9 (9): Multiply Factor is 25 10 (10): Multiply Factor is 26 11 (11): Multiply Factor is 27 12 (12): Multiply Factor is 28 13 (13): Multiply Factor is 29 14 (14): Multiply Factor is 30 15 (15): Multiply Factor is 31 16 (16): Multiply Factor is 32 17 (17): Multiply Factor is 33 18 (18): Multiply Factor is 34 19 (19): Multiply Factor is 35 20 (20): Multiply Factor is 36 21 (21): Multiply Factor is 37 22 (22): Multiply Factor is 38 23 (23): Multiply Factor is 39 24 (24): Multiply Factor is 40 25 (25): Multiply Factor is 41 26 (26): Multiply Factor is 42 27 (27): Multiply Factor is 43 28 (28): Multiply Factor is 44 29 (29): Multiply Factor is 45 30 (30): Multiply Factor is 46 31 (31): Multiply Factor is 47 |
CME0 | Clock Monitor Enable 0 (0): External clock monitor is disabled for OSC0. 1 (1): External clock monitor is enabled for OSC0. |
PLLS | PLL Select 0 (0): FLL is selected. 1 (1): PLL is selected (PRDIV 0 need to be programmed to the correct divider to generate a PLL reference clock in the range of 8-16 MHz prior to setting the PLLS bit). |
LOLIE0 | Loss of Lock Interrrupt Enable 0 (0): No interrupt request is generated on loss of lock. 1 (1): Generate an interrupt request on loss of lock. |